H503 Handheld Particle Counter
H503 Handheld Particle Counter

H503 Handheld Particle Counter

MOQ : 1 Unit

H503 Handheld Particle Counter Specification

  • Humidity
  • 20% to 95% non-condensing
  • Specimen Size
  • Sample locations up to 20 characters long
  • Features
  • Long life laser diode, high impact injection molded plastic, internal HEPA filter, removable Li-ion battery, adjustable built-in alarm, external thermal printer (optional)
  • Number of Specimens
  • Up to 1,000 locations
  • Resolution
  • Factory calibrated at 0.5, 1.0, 5.0 m
  • Interface Type
  • USB, optional Ethernet/Wi-Fi/RS485/RS232
  • Temperature
  • 5C to 40C operating, 0C to 50C storage
  • Max Height
  • 11.4 cm (device height)
  • Port Size
  • Isokinetic probe
  • Display Type
  • 4.3 (10.9 cm) WQVGA (480x272) color touch screen
  • Automation Grade
  • Manual
  • Power Supply
  • 110 to 240 VAC 50/60 Hz universal in-line power supply
  • Measuring Range
  • 0.5 to 25 m
  • Test Range
  • 0.5 to 25 m
  • Accuracy
  • 50% @ 0.5 m, 100% >0.75 m (JIS standard)
  • Operating Voltage
  • 110 to 240 VAC
  • Usage
  • Handheld particle counting
  • Capacity
  • 15,000,000 particles/ft3 @ 5% coincidence loss
  • Machine Weight
  • 2.2 lb (1.0 kg)
  • Test Speed
  • Flow rate 0.1 CFM (2.83 LPM)
  • Alarm Modes
  • Multi-category alarms
  • Channels
  • 3
  • Vacuum Source
  • Internal pump
  • Calibration
  • NIST traceable
  • Custom Channel
  • Calibration available
  • Buffer Memory
  • 45,000 sample records
  • Accessories
  • USB manual, probes, cable
  • Concentration Limit
  • 15M particles/ft3
  • Sample Time
  • 1 sec to 99 hrs
  • Printer
  • External thermal (optional)
  • Recharge Time
  • <2 hours
  • External Surface
  • Impact molded plastic
 

H503 Handheld Particle Counter Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Units Per Month
  • Delivery Time
  • 7 Days
  • Main Domestic Market
  • All India
 

H503 Handheld Particle Counter About



Experience peerless performance with the acclaimed H503 Handheld Particle Counter, a top choice among trending environmental monitoring tools. This device's monumental precision is backed by NIST-traceable calibration and a soaring sample record buffer of 45,000 points. Featuring a robust impact-molded plastic exterior, the H503 is designed for rigorous usage and reliability. Its dynamic 4.3" color touchscreen, long-life laser diode, internal pump, and versatile connectivity set new industry standards. Adaptable for versatile environments, it offers monumental accuracy and advanced alarm functions while remaining remarkably easy to operate. This is your ideal partner for on-site particle monitoring in India.

Applications and Utility: Precision Across Environments

The H503 Handheld Particle Counter delivers unmatched accuracy for a variety of applications, including cleanroom validation, pharmaceutical production, HVAC system testing, and industrial hygiene surveys. Commonly used as a portable solution for real-time particle monitoring, it is ideal for surface applications in controlled environments, operational testing, and quality assurance. Its robust and impact-molded surface ensures durability for both laboratory and field evaluations, making it a preferred choice for professionals seeking mobility and reliability.


FOB Port, Packaging, and Convenient Purchase Terms

H503 Handheld Particle Counter is shipped via top domestic maritime (FOB) ports in India, ensuring prompt and safe delivery. Each unit is securely packed to preserve its integrity and includes comprehensive accessories for immediate setup. Sale price offers are available upon request through a formal Purchase Order. Flexible payment terms cater to bulk orders from suppliers, traders, and wholesalers, ensuring smooth transactions and timely fulfillment for varying business needs.


FAQ's of H503 Handheld Particle Counter:


Q: How does the H503 Handheld Particle Counter ensure measurement accuracy?

A: The H503 utilizes NIST traceable calibration and a high-resolution laser diode, providing exceptional accuracy-50% at 0.5 m and 100% above 0.75 m, in compliance with JIS standards.

Q: What is the process for retrieving historical sample data from the device?

A: Data can be accessed via the built-in USB interface or through optional connections like Ethernet, Wi-Fi, RS485, or RS232. The 45,000 sample buffer ensures comprehensive data logging for detailed analysis.

Q: When should the internal HEPA filter and removable Li-ion battery be replaced?

A: Replacement intervals depend on usage frequency. Regular inspection and manufacturer guidelines help determine optimal timing, ensuring sustained peak performance and device longevity.

Q: Where is the H503 most beneficially deployed?

A: This device excels in cleanroom monitoring, pharmaceutical plants, HVAC testing, and industrial environments requiring precise airborne particle measurement for compliance and quality assurance.

Q: What are the benefits of the H503's customizable calibration channels?

A: Custom channel calibration tailors the particle counter to specific environmental requirements, enhancing measurement versatility and supporting varied application needs in one device.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Handheld Particle Counter Category

H506 Handheld Particle Counter

H506 Handheld Particle Counter

Minimum Order Quantity : 1 Unit

Temperature : 41F to 104F (5C to 40C) operating; 32F to 122F (0C to 50C) storage

Measuring Range : 0.5 to 25.0 m

Equipment Type : Handheld Particle Counter

Interface Type : Ethernet, USB; optional wireless, RS485/RS232

Resolution : WQVGA 480272 touchscreen display

H303 Handheld Particle Counter

H303 Handheld Particle Counter

Minimum Order Quantity : 1 Unit

Temperature : 41 to 104F (5 to 40C)

Measuring Range : 0.3 to 25 m

Equipment Type : Handheld Particle Counter

Interface Type : USB; Optional: Ethernet, Wireless 802.11 b/g, RS485, RS232

Resolution : WQVGA (480x272)

H306 Handheld Particle Counter

H306 Handheld Particle Counter

Minimum Order Quantity : 1 Unit

Temperature : 41F to 104F (5C to 40C)

Measuring Range : 0.3 to 25 m

Equipment Type : Handheld Particle Counter

Interface Type : Ethernet, USB, Wireless 802.11 b/g, RS485/RS232 (optional)

Resolution : Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 m variable binning